Some AV blocks are benign, or normal, in certain people, such as in athletes or children. Other blocks are pathologic, or abnormal, and have several causes, including ischemia, infarction, fibrosis, and drugs.

Classification

There are three types, or degrees, of AV block: (1) first-degree, (2) second-degree, and (3) third-degree, with third-degree being the most severe. An ECG is used to differentiate between the different types of AV blocks. However, one important consideration when diagnosing AV blocks from ECGs is the possibility of pseudo- AV blocks which are due to concealed junctional extrasystoles. It is important to diagnose AV-blocks precisely because unnecessary pacemaker placement in patients with pseudo-AV blocks can worsen symptoms and create complications.

First-degree atrioventricular block

First-degree AV block occurs when there is a delay, but not disruption, as the electrical signal moves between the atrium and the ventricles through the AV node. On ECG, this is defined by a PR interval greater than 200 msec. Additionally, there are no dropped, or skipped, beats.

Second-degree atrioventricular block


Second-degree AV block occurs when the electrical signal between the atria and ventricles is even more impaired than in a first-degree AV block. In a second-degree AV block, the impairment results in a failure to conduct an impulse, which causes a skipped beat.

Mobitz I

Mobitz I is characterized by a progressive yet reversible block of the AV node. On ECG, this is defined by progressive prolongation of the PR interval, with a resulting dropped beat (the PR interval gets longer and longer until a beat is finally dropped, or skipped).

Some patients are asymptomatic; those who have symptoms respond to treatment effectively. There is a low risk of a Mobitz I AV block leading to complete heart block or cardiac arrest.

Mobitz II

Mobitz II is caused by a sudden, unexpected failure of the His-Purkinje cells to conduct the electrical impulse. On ECG, the PR interval is unchanged from beat to beat, but there is a sudden failure to conduct the signal to the ventricles, and resulting in random skipped beat.

The risks and possible effects of Mobitz II are much more severe than Mobitz I in that the risk of progression to complete heart block or asystole are significant.

Third-degree atrioventricular block

Third-degree AV block occurs when the signal between the atria and ventricles is completely blocked, and there is no communication between the two. None of the signals from the upper chambers make it to the lower chambers. On ECG, there is no relationship between P waves and QRS complexes, meaning the P waves and QRS complexes are not in a 1:1 ratio.

Third-degree AV block is the most severe of the AV blocks. Persons with third-degree AV block need emergency treatment including but not limited to a pacemaker.