Fetal heart sounds were described as early as 350 years ago and approximately 200 years ago mechanical stethoscopes, such as the Pinard horn, were introduced in clinical practice.

Modern-day CTG was developed and introduced in the 1950s and early 1960s by Edward Hon, Roberto Caldeyro-Barcia and Konrad Hammacher. The first commercial fetal monitor (Hewlett-Packard 8020A) was released in 1968.

CTG monitoring is widely used to assess fetal well-being by identifying babies at risk of hypoxia (lack of oxygen). CTG is mainly used during labour. A review found that in the antenatal period (before labour), there is no evidence to suggest that monitoring women with high-risk pregnancies benefits the mother or baby, although research around this is old and should be interpreted with caution. Up-to-date research is needed to provide more information surrounding this practice.

A study found that CTG monitoring didn't significantly improve or worsen the outcome, in terms of preventable child death, post birth mortality, of pregnancy for high risk mothers. But the evidence examined in the study is quite old and there have been significant changes in medical care since then.

Methods

External cardiotocography can be used for continuous or intermittent monitoring. The fetal heart rate and the activity of the uterine muscle are detected by two transducers placed on the mother's abdomen, with one above the fetal heart to monitor heart rate, and the other at the fundus of the uterus to measure frequency of contractions. Doppler ultrasound provides the information, which is recorded on a paper strip known as a cardiotocograph (CTG). External tocometry is useful for showing the beginning and end of contractions as well as their frequency, but not the strength of the contractions. The absolute values of pressure readings on an external tocometer are dependent on position and are not sensitive in people who are obese. In cases where information on the strength or precise timing of contractions is needed, an internal tocometer is more appropriate.

Internal cardiotocography uses an electronic transducer connected directly to the fetus. A wire electrode, sometimes called a spiral or scalp electrode, is attached to the fetal scalp through the cervical opening and is connected to the monitor. Internal monitoring provides a more accurate and consistent transmission of the fetal heart rate, as unlike external monitoring, it is not affected by factors such as movement. Internal monitoring may be used when external monitoring is inadequate, or if closer surveillance is needed. Internal tocometry can only be used if the amniotic sac is ruptured (either spontaneously or artificially) and the cervix is open. To gauge the strength of contractions, a small catheter (called an intrauterine pressure catheter or IUPC) is passed into the uterus past the fetus. Combined with an internal fetal monitor, an IUPC may give a more precise reading of the baby's heart rate and the strength of contractions.

A typical CTG reading is printed on paper and may be stored on a computer for later reference. A variety of systems for centralized viewing of CTG have been installed in maternity hospitals in industrialised countries, allowing simultaneous monitoring of multiple tracings in one or more locations. Display of maternal vital signs, ST signals and an electronic partogram are available in the majority of these systems. A few of them have incorporated computer analysis of cardiotocographic signals or combined cardiotocographic and ST data analysis.