Cascading failures may occur when one part of the system fails. When this happens, other parts must then compensate for the failed component. This in turn overloads these nodes, causing them to fail as well, prompting additional nodes to fail one after another.

In power transmission

Cascading failure is common in power grids when one of the elements fails (completely or partially) and shifts its load to nearby elements in the system. Those nearby elements are then pushed beyond their capacity so they become overloaded and shift their load onto other elements. Cascading failure is a common effect seen in high voltage systems, where a single point of failure (SPF) on a fully loaded or slightly overloaded system results in a sudden spike across all nodes of the system. This surge current can induce the already overloaded nodes into failure, setting off more overloads and thereby taking down the entire system in a very short time.

This failure process cascades through the elements of the system like a ripple on a pond and continues until substantially all of the elements in the system are compromised and/or the system becomes functionally disconnected from the source of its load. For example, under certain conditions a large power grid can collapse after the failure of a single transformer.

Monitoring the operation of a system, in real-time, and judicious disconnection of parts can help stop a cascade. Another common technique is to calculate a safety margin for the system by computer simulation of possible failures, to establish safe operating levels below which none of the calculated scenarios is predicted to cause cascading failure, and to identify the parts of the network which are most likely to cause cascading failures.

One of the primary problems with preventing electrical grid failures is that the speed of the control signal is no faster than the speed of the propagating power overload, i.e. since both the control signal and the electrical power are moving at the same speed, it is not possible to isolate the outage by sending a warning ahead to isolate the element.

Examples

Cascading failure caused the following power outages:

  • Blackout in Northeast America in 1965
  • Blackout in Southern Brazil in 1999
  • Blackout in Northeast America in 2003
  • Blackout in Italy in 2003
  • Blackout in London in 2003
  • European Blackout in 2006
  • Blackout in Northern India in 2012
  • Blackout in South Australia in 2016
  • Blackout in southeast South America in 2019
  • Countrywide blackout in Kenya 2022
  • Countrywide blackout in Kenya 2023