Lably
Skip to content

Decompression (diving)

  • 16 min read
  • 3 chapters

Related on Lably

Through Breathing gas, Pressure and Nitrogen

When a diver descends in the water, the hydrostatic pressure, and therefore the ambient pressure, rises. Because breathing gas is supplied at ambient pressure, some of this gas dissolves into the diver's blood and is transferred by the blood to other tissues. Inert gas such as nitrogen or helium continues to be taken up until the gas dissolved in the diver is in a state of equilibrium with the breathing gas in the diver's lungs, at which point the diver is saturated for that depth and breathing mixture, or the depth, and therefore the pressure, is changed, or the partial pressures of the gases are changed by modifying the breathing gas mixture. During ascent, the ambient pressure is reduced, and at some stage the inert gases dissolved in any given tissue will be at a higher concentration than the equilibrium state and start to diffuse out again. If the pressure reduction is sufficient, excess gas may form bubbles, which may lead to decompression sickness, a possibly debilitating or life-threatening condition. It is essential that divers manage their decompression to avoid excessive bubble formation and decompression sickness. A mismanaged decompression usually results from reducing the ambient pressure too quickly for the amount of gas in solution to be eliminated safely. These bubbles may block arterial blood supply to tissues or directly cause tissue damage. If the decompression is effective, the asymptomatic venous microbubbles present after most dives are eliminated from the diver's body in the alveolar capillary beds of the lungs. If they are not given enough time, or more bubbles are created than can be eliminated safely, the bubbles grow in size and number causing the symptoms and injuries of decompression sickness. The immediate goal of controlled decompression is to avoid development of symptoms of bubble formation in the tissues of the diver, and the long-term goal is to avoid complications due to sub-clinical decompression injury.

The mechanisms of bubble formation and the damage bubbles cause has been the subject of medical research for a considerable time and several hypotheses have been advanced and tested. Tables and algorithms for predicting the outcome of decompression schedules for specified hyperbaric exposures have been proposed, tested and used, and in many cases, superseded. Although constantly refined and generally considered acceptably reliable, the actual outcome for any individual diver remains slightly unpredictable. Although decompression retains some risk, this is now generally considered acceptable for dives within the well tested range of normal recreational and professional diving. Nevertheless, currently popular decompression procedures advise a 'safety stop' additional to any stops required by the algorithm, usually of about three to five minutes at 3 to 6 metres (10 to 20 ft), particularly 1 on an otherwise continuous no-stop ascent.

Decompression may be continuous or staged. A staged decompression ascent is interrupted by decompression stops at calculated depth intervals, but the entire ascent is actually part of the decompression and the ascent rate is critical to harmless elimination of inert gas. A no-decompression dive, or more accurately, a dive with no-stop decompression, relies on limiting the ascent rate for avoidance of excessive bubble formation in the fastest tissues. The elapsed time at surface pressure immediately after a dive is also an important part of decompression and can be thought of as the last decompression stop of a dive. It can take up to 24 hours for the body to return to its normal atmospheric levels of inert gas saturation after a dive. When time is spent on the surface between dives this is known as the "surface interval" and is considered when calculating decompression requirements for the subsequent dive.

Efficient decompression requires the diver to ascend fast enough to establish as high a decompression gradient, in as many tissues, as safely possible, without provoking the development of symptomatic bubbles. This is facilitated by the highest acceptably safe oxygen partial pressure in the breathing gas, and avoiding gas changes that could cause counterdiffusion bubble formation or growth. The development of schedules that are both safe and efficient has been complicated by the large number of variables and uncertainties, including personal variation in response under varying environmental conditions and workload.

Decompression theory

Decompression theory is the study and modelling of the transfer of the inert gas component of breathing gases from the gas in the lungs to the tissues of the diver and back during exposure to variations in ambient pressure. In the case of underwater diving and compressed air work, this mostly involves ambient pressures greater than the local surface pressure—but astronauts, high altitude mountaineers, and occupants of unpressurised aircraft, are exposed to ambient pressures less than standard sea level atmospheric pressure. In all cases, the symptoms of decompression sickness occur during or within a relatively short period of hours, or occasionally days, after a significant reduction of ambient pressure.

Physics and physiology of decompression

The absorption of gases in liquids depends on the solubility of the specific gas in the specific liquid, the concentration of gas, customarily expressed as partial pressure, and temperature. The main variable in the study of decompression theory is pressure.

Once dissolved, distribution of the dissolved gas may be by diffusion, where there is no bulk flow of the solvent, or by perfusion where the solvent (in this case blood) is circulated around the diver's body, where gas can diffuse to local regions of lower concentration. Given sufficient time at a specific partial pressure in the breathing gas, the concentration in the tissues stabilises, or saturates, at a rate that depends on solubility, diffusion rate and perfusion, all of which vary in the different tissues of the body. This process is referred to as in-gassing, and is usually modelled as an inverse exponential process.

If the concentration of the inert gas in the breathing gas is reduced below that of any of the tissues, there is a tendency for gas to return from the tissues to the breathing gas. This is known as out-gassing, and occurs during decompression, when the reduction in ambient pressure reduces the partial pressure of the inert gas in the lungs. This process may be complicated by the formation of gas bubbles, and the modelling is more complex and varied.

The combined concentrations of gases in any given tissue depend on the history of pressure and gas composition. Under equilibrium conditions, the total concentration of dissolved gases is less than the ambient pressure—as oxygen is metabolised in the tissues, and the carbon dioxide produced is much more soluble. However, during a reduction in ambient pressure, the rate of pressure reduction may exceed the rate at which gas is eliminated by diffusion and perfusion. If the concentration gets too high, it may reach a stage where bubble formation can occur in the supersaturated tissues. When the pressure of gases in a bubble exceed the combined external pressures of ambient pressure and the surface tension of the bubble-liquid interface, the bubbles grow, and this growth can damage tissue.

If the dissolved inert gases come out of solution within the tissues of the body and form bubbles, they may cause the condition known as decompression sickness, or DCS, also known as divers' disease, the bends or caisson disease. However, not all bubbles result in symptoms, and Doppler bubble detection shows that venous bubbles are present in a significant number of asymptomatic divers after relatively mild hyperbaric exposures.

Since bubbles can form in or migrate to any part of the body, DCS can produce many symptoms, and its effects may vary from joint pain and rashes to paralysis and death. Individual susceptibility can vary from day to day, and different individuals under the same conditions may be affected differently or not at all. The classification of types of DCS by its symptoms has evolved since its original description.

The risk of decompression sickness after diving can be managed through effective decompression procedures and contracting it is now uncommon, though it remains to some degree unpredictable. Its potential severity has driven much research to prevent it and divers almost universally use decompression tables or dive computers to limit or monitor their exposure and to control their ascent speed and decompression procedures. If DCS is contracted, it is usually treated by hyperbaric oxygen therapy in a recompression chamber. If treated early, there is a significantly higher chance of successful recovery.

A diver who only breathes gas at atmospheric pressure when free-diving or snorkelling will not usually need to decompress but it is possible to get decompression sickness, or taravana, from repetitive deep free-diving with short surface intervals.

Decompression models

Actual rates of diffusion and perfusion, and solubility of gases in specific physiological tissues are not generally known, and vary considerably. However mathematical models have been proposed that approximate the real situation to a greater or lesser extent. These models predict whether symptomatic bubble formation is likely to occur for a given dive profile. Algorithms based on these models produce decompression tables. In personal dive computers, they produce a real-time estimate of decompression status and display a recommended ascent profile for the diver, which may include decompression stops.

Two different concepts have been used for decompression modelling. The first assumes that dissolved gas is eliminated while in the dissolved phase, and that bubbles are not formed during asymptomatic decompression. The second, which is supported by experimental observation, assumes that bubbles are formed during most asymptomatic decompressions, and that gas elimination must consider both dissolved and bubble phases.

Early decompression models tended to use the dissolved phase models, and adjusted them by factors derived from experimental observations to reduce the risk of symptomatic bubble formation.

There are two main groups of dissolved phase models: In parallel compartment models, several compartments with varying rates of gas absorption (half time), are considered to exist independently of each other, and the limiting condition is controlled by the compartment that shows the worst case for a specific exposure profile. These compartments represent conceptual tissues and do not represent specific organic tissues. They merely represent the range of possibilities for the organic tissues. The second group uses serial compartments, which assumes that gas diffuses through one compartment before it reaches the next.

More recent models attempt to model bubble dynamics, also usually by simplified models, to facilitate the computation of tables, and later to allow real time predictions during a dive. Models that approximate bubble dynamics are varied. They range from those that are not much more complex than the dissolved phase models, to those that require considerably greater computational power. Bubble models have not been experimentally shown to be more efficient, nor to reduce risk of decompression sickness for dives where the bottom profile and total ascent time are the same as for dissolved gas models. Limited experimental work suggests that for some dive profiles the increased ingassing due to deeper stops may cause greater decompression stress in slower tissues with consequent greater venous bubble loading after dives.

Sign in to keep reading

2 more chapters are free with a Lably account.

More in Health