Lably
Skip to content

Duplex sequencing

Preparation and analysis method for DNA

  • 9 min read
  • 6 chapters

Related on Lably

Through Mosaic (genetics), DNA extraction and Restriction enzyme

This method uses degenerate molecular tags in addition to sequencing adapters to recognize reads originating from each strand of DNA. As the two strands are complementary, true mutations are found at the same position in both strands. In contrast, PCR or sequencing errors result in mutations in only one strand and can thus be discounted as technical error. Duplex sequencing theoretically can detect mutations with frequencies as low as 5 × 10−8 --that is more than 10,000 times higher in accuracy compared to the conventional next-generation sequencing methods.

The estimated error rate of standard next-generation sequencing platforms is 10−2 to 10−3 per base call. With this error rate, billions of base calls that are produced by NGS will result in millions of errors. The errors are introduced during sample preparation and sequencing such as polymerase chain reaction, sequencing, and image analysis errors. While the NGS platforms' error rate is acceptable in some applications such as detection of clonal variants, it is a major limitation for applications that require higher accuracy for detection of low-frequency variants such as detection of intra-organismal mosaicism, subclonal variants in genetically heterogeneous cancers, or circulating tumor DNA.

Several library preparation strategies have been developed that increase accuracy of NGS platforms such as molecular barcoding and circular consensus sequencing method. Like NGS platforms, the data generated by these methods originates from a single strand of DNA, and therefore the errors that are introduced during PCR amplification, tissue processing, DNA extraction, hybridization capture (where used) or DNA sequencing itself can still be distinguished as a true variant. The duplex sequencing method addresses this problem by taking advantage of the complementary nature of two strands of DNA and confirming only variants that are present in both strands of DNA. Because the probability of two complementary errors arising at the same location in both strands is exceedingly low, duplex sequencing increases the accuracy of sequencing significantly.

Experimental workflow

Duplex sequencing tagged adapters can be used in combination with the majority of NGS adapters. In the figures and workflow section of this article, Illumina sequencing adapters are used as an example following the original published protocol.

Adapter annealing

Two oligonucleotides are used for this step (Figure 1: Adapter oligos). One of the oligonucleotides contains a 12-nucleotide single-stranded random tag sequence followed by a fixed 5' nucleotide sequence (black sequence in Figure 1). In this step, oligonucleotides are annealed in a complementary region by incubation at the required temporal condition.

Adapter synthesis

The adapters that annealed successfully are extended and synthesized by a DNA polymerase to complete a double-stranded adapter containing complementary tags (Figure 1).

3’-dT-tailing

The extended double-stranded adapters are cleaved by HpyCH4III at a specific restriction site located at 3’ side of the tag sequence and will result in a 3’-dT overhang that will be ligated to the 3’-dA overhang on DNA libraries in the adapter ligation step (Figure 1).

Library preparation

Double-stranded DNA is sheared using one of these methods: sonication, enzymatic digestion, or nebulization. Fragments are size selected using Ampure XP beads. Gel-based size selection is not recommended since it can cause melting of DNA double strands and DNA damage due to UV exposure. The size of selected fragments of DNA are subjected to 3’-end-dA-tailing.

Adapter ligation

In this step, two tagged adapters are ligated from 3’-dT-tails to 3’-dA-tails on both sides of double-stranded DNA library fragments. This process results in double-stranded library fragments that contain two random tags (α and β) on each side that are the reverse complement of each other (Figure 1 and 2). The "DNA: adapter" ratio is crucial in determining the success of ligation.

Insertion of sequencing adapters to tagged libraries

In the last step of duplex sequencing library preparation, Illumina sequencing adapters are added to the tagged double stranded libraries by PCR amplification using primers containing sequencing adapters. During PCR amplification, both complementary strands of DNA are amplified and generate two types of PCR products. Product 1 derives from strand 1's which have a unique tag sequence (called α in Figure 2) next to the Illumina adapter 1 and product 2 has a unique tag (called β in Figure 2) next to the Illumina adapter 1. (In each strand, tag α is the reverse complement of tag β and vice versa). The libraries containing duplex tags and Illumina adapters are sequenced using the Illumina TruSeq system. Reads that are originating from every single strand of DNA form a group of reads (tag families) that share the same tag. The detected families of reads will be used in the next step for analyzing sequencing data.

Considerations

Efficiency of adapter ligation

Adapter ligation efficiency is very important in successful duplex sequencing. An extra amount of libraries or adapters can affect the DNA to adapter balance, resulting in inefficient ligation and an excess amount of primer dimers, respectively. Therefore, it is important to keep the molar concentration of DNA to adapter at the optimal ratio (0.05).

Tag family size

The efficiency of duplex sequencing depends on the final number of DCSs which is directly related to the number of reads in each family (family size). If the family size is too small then the DCS can not be assembled and if too many reads are sharing the same tag, the data yield will be low. Family size is determined by the amount of DNA template needed for PCR amplification and the dedicated sequencing lane fraction. The optimal tag family size is between 6 and 12 members. To obtain the optimal family size, the amounts of DNA template and the dedicated sequencing lane fraction need to be adjusted. The following formula takes into account the most important variables that can affect depth of coverage (N=40DG÷R) where "N" is the number of reads, "D" is the desired depth of coverage, "G" is the size of DNA target in base pair, and "R" is final read length.