Lably
Skip to content

Epitranscriptomic sequencing

  • 22 min read
  • 10 chapters

Related on Lably

Through Covalent bond, Peptide and Recombinant DNA

There are seven major classes of chemical modifications found in RNA molecules: N6-methyladenosine, 2'-O-methylation, N6,2'-O-dimethyladenosine, 5-methylcytidine, 5-hydroxylmethylcytidine, inosine, and pseudouridine. Various sequencing methods have been developed to profile each type of modification. The scale, resolution, sensitivity, and limitations associated with each method and the corresponding bioinformatics tools used will be discussed.

Methods for profiling N6-methyladenosine

Methylation of adenosine does not affect its ability to base-pair with thymidine or uracil, so N6-methyladenosine (m6A) cannot be detected using standard sequencing or hybridization methods. This modification is marked by the methylation of the adenosine base at the nitrogen-6 position. It is abundantly found in polyA+ mRNA; also found in tRNA, rRNA, snRNA, and long ncRNA.

m6A-seq and MeRIP-seq

In 2012, the first two methods for m6A sequencing came out that enabled transcriptome-wide profile of m6A in mammalian cells. These two techniques, called m6A-seq and MeRIP-seq (m6A-specific methylated RNA immunoprecipitation), are also the first methods to allow for any type of RNA modification sequencing. These methods were able to detect 10,000 m6A peaks in the mammalian transcriptome; the peaks were found to be enriched in 3’UTR regions, near STOP codons, and within long exons.

The two methods were optimized to detect methylation peaks in poly(A)+ mRNA, but the protocol could be adapted to profile any type of RNA. Collected RNA sample is fragmented into ~100-nucleotide-long oligonucleotides using a fragmentation buffer, immunoprecipitation with purified anti-m6A antibody, elution and collection of antibody-tagged RNA molecules. The immunoprecipitation procedure in MeRIP-Seq is able to produce >130fold enrichment of m6A sequences. Random primed cDNA library generation was performed, followed by adaptor ligation and Illumina sequencing. Since the RNA strands are randomly chopped up, the m6A site should, in principle, lie somewhere in the center of the regions to which sequence reads align. At extremes, the region would be roughly 200nt wide (100nt up- and downstream of the m6A site).

When the first nucleotide of a transcript is an adenosine, in addition to the ribose 2’-O-methylation, this base can be further methylated at the N6 position. m6A-seq was confirmed to be able to detect m6Am peaks at transcription start sites. Adapter ligation at both ends of RNA fragment results in reads tending to pileup at the 5’ terminus of the transcript. Schwartz et al. (2015) leveraged this knowledge to detect mTSS sites by picking out sites with a high ratio of the size of pileups in the IP samples compared to input sample. As confirmation, >80% of the highly enriched pileup sites contained adenosine.

The resolution of these methods is 100-200nt, which was the range of the fragment size. These two methods had several drawbacks: (1) required substantial input material, (2) low resolution which made pinpointing the actual site with the m6A mark difficult, and (3) cannot directly assess false positives.

Especially in MeRIP-Seq, the bioinformatics tools that are currently available are only able to call 1 site per ~100-200nt wide peak, so a substantial portion of clustered m6As (~64nt between each individual site within a cluster) are missed. Each cluster can contain up to 15 m6A residues.

In 2013, a modified version of m6A-seq based on the previous two methods m6A-seq and MeRIP-seq came out which aimed to increase resolution, and demonstrated this in the yeast transcriptome. They achieved this by decreasing fragment size and employing a ligation-based strand-specific library preparation protocol capturing both ends of the fragmented RNA, ensuring that the methylated position is within the sequenced fragment. By additionally referencing the m6A consensus motif and eliminating false positive m6A peaks using negative control samples, the m6A profiling in yeast was able to be done at single-base resolution.

UV-based Methods

PA-m6A-seq

UV-induced RNA-antibody crosslinking was added on top of m6A-seq to produce PA-m6A-seq (photo-crosslinking-assisted m6A-seq) which increases resolution up to ~23nt. First, 4-thiourodine (4SU) is incorporated into the RNA by adding 4SU in growth media, some incorporation sites presumably near m6A location. Immunoprecipitation is then performed on full-length RNA using m6A-specific antibody [36]. UV light at 365 nm is then shined onto RNA to activate the crosslinking to the antibody with 4SU. Crosslinked RNA was isolated via competition elution and fragmented further to ~25-30nt; proteinase K was used to dissociate the covalent bond between crosslinking site and antibody. Peptide fragments that remain after antibody removal from RNA cause the base to be read as a C as opposed to a T during reverse transcription, effectively inducing a point mutation at the 4SU crosslinking site. The short fragments are subjected to library construction and Illumina sequencing, followed by finding the consensus methylation sequence. The presence of the T to C mutation helps increase the signal to noise ratio of methylation site detection as well as providing greater resolution to the methylation sequence. One shortcoming of this method is that m6A sites that did not incorporate 4SU can't be detected. Another caveat is that position of 4SU incorporation can vary relative to any single m6A residue, so it still remains challenging to precisely locate m6A site using the T to C mutation.

m6A-CLIP and miCLIP

m6A-CLIP (crosslinking immunoprecipitation) and miCLIP (m6A individual-nucleotide-resolution crosslinking and immunoprecipitation) are UV-based sequencing techniques. These two methods activate crosslinking at 254 nm, fragments RNA molecules before immunoprecipitation with antibody, and do not depend on the incorporation of photoactivatable ribonucleosides - the antibody directly crosslinks with a base close (very predictable location) to the m6A site. These UV-based strategies uses antibodies that induces consistent and predictable mutational and truncation patterns in the cDNA strand during reverse-transcription that could be leveraged to more precisely locate the m6A site. Though both m6A-CLIP and miCLIP reply on UV induced mutations, m6A-CLIP is distinct by taking advantage that m6A alone can induce cDNA truncation during reverse transcription and generate single-nucleotide mapping for over ten folds more precise m6A sites (MITS, m6A-induced truncation sites), permitting comprehensive and unbiased precise m6A mapping. In contrast, UV-mapped m6A sites by miCLIP is only a small subset of total precise m6A sites. The precise location of tens of thousands of m6A sites in human and mouse mRNAs by m6A-CLIP reveals that m6A is enriched at last exon but not around stop codon.

In m6A-CLIP and miCLIP, RNA is fragmented to ~20-80nt first, then the 254 nm UV-induced covalent RNA/m6A antibody complex was formed in the fragments containing m6A. The antibody was removed with proteinase K before reverse-transcription, library construction and sequencing. Remnants of peptides at the crosslinking site on the RNA after antibody removal, leads to insertions, truncations, and C to T mutations during reverse transcription to cDNA, especially at the +1 position to the m6A site (5’ to the m6A site) in the sequence reads. Positive sites seen using m6A-CLIP and miCLIP had high percent of matches with those detected using SCARLET, which has higher local resolution around a specific site, (see below), implicating m6A-CLIP and miCLIP has high spatial resolution and low false discovery rate. miCLIP has been used to detect m6Am by looking at crosslinking-induced truncation sites at the 5’UTR.

Methods for quantifying m6A modification status

Although m6A sites could be profiled at high resolution using UV-based methods, the stoichiometry of m6A sites - the methylation status or the ratio m6A+ to m6A- for each individual site within a type of RNA - is still unknown. SCARLET (2013) and m6A-LAIC-seq (2016) allows for the quantitation of stoichiometry at a specific locus and transcriptome-wide, respectively.

Bioinformatics methods used to analyze m6A peaks do not make any prior assumptions about the sequence motifs within which m6A sites are usually found, and take into consideration all possible motifs. Therefore, it is less likely to miss sites.

SCARLET

SCARLET (site-specific cleavage and radioactive-labeling followed by ligation-assisted extraction and thin-layer chromatography) is used determining the fraction of RNA in a sample that carries a methylated adenine at a specific site. One can start with total RNA without having to enrich for the target RNA molecule. Therefore, it is an especially suitable method for quantifying methylation status in low abundance RNAs such as tRNAs. However, it is not suitable or practical for large-scale location of m6A sites.

The procedure begins with a chimeric DNA oligonucleotide annealing to the target RNA around the candidate modification site. The chimeric ssDNA has 2’OMe/2’H modifications and is complementary to the target sequence. The chimeric oligonucleotide serves as a guide to allow RNase H to cleave the RNA strand precisely at the 5’-end of the candidate site. The cut site is then radiolabeled with phosphorus-32 and splint-ligated to a 116nt ssDNA oligonucleotide using DNA ligase. RNase T1/A is introduced to the sample to digest all RNA, except for the RNA molecules with the 116-mers DNA attached. This radiolabeled product is then isolated and digested by nuclease to generate a mixture of modified and unmodified adenosines (5’P-m6A and 5’-P-A) which is separated using thin layer chromatography. The relative proportions of the two groups can be determined using UV absorption levels.

m6A-LAIC-seq

m6A-LAIC-seq (m6A-level and isoform-characterization sequencing) is a high-throughput approach to quantify methylation status on a whole-transcriptome scale. Full-length RNA samples are used in this method. RNAs are first subjected to immunoprecipitation with an anti-m6A antibody. Excess antibody is added to the mixture to ensure all m6A-containing RNAs are pulled down. The mixture is separated into eluate (m6A+ RNAs) and supernatant (m6A- RNAs) pools. External RNA Controls Consortium (ERCC) spike ins are added to the eluate and supernatant, as well as an independent control arm consisting of just ERCC spike in. After antibody cleavage in the eluate pool, each of the three mixtures are sequenced on a next generation sequencing platform. The m6A levels per site or gene could be quantified by the ERCC-normalized RNA abundances in different pools. Since full-length RNA is used, it is possible to directly compare alternatively spliced isoforms between the m6A+ and m6A- fractions as well as comparing isoform abundance within the m6A+ portion.

Despite the advances in m6A-sequencing, several challenges still remain: (1) A method has yet to be developed that characterizes the stoichiometry between different sites in the same transcript; (2) Analysis results are heavily dependent on the bioinformatics algorithm used to call the peaks; (3) Current methods all use m6A-specific antibodies to tag m6A sites, but it has been reported that the antibodies contain intrinsic bias for RNA sequences.