Heat index

Temperature index that accounts for the effects of humidity

  • 7 min read
  • 7 chapters

Related on Lably

Through Temperature, Humidity and Evaporative cooler

The human body normally cools itself largely by evaporation of sweat. High relative humidity reduces evaporation and cooling, increasing discomfort and potential heat stress. Different individuals perceive heat differently on the basis of body shape, metabolism, level of hydration, pregnancy, other physical conditions, acclimatisation, and even psychological factors. Measurement of perceived temperature has been based on reports of how hot subjects feel under controlled conditions of temperature and humidity. Besides the heat index, other measures of apparent temperature include the Canadian humidex, the wet-bulb globe temperature, the "relative outdoor temperature", and the proprietary "RealFeel". A term sometimes translated as "heat index" but not accounting for humidity is the national thermal indicator—indicateur thermique national (ITN)−of France, an average of temperature readings at 30 mainland weather stations used to track temperature trends and define heatwaves.

History

The heat index theoretical structure and supporting equations were developed in 1979 by Robert G. Steadman. Like the wind chill index, the heat index contains assumptions about the human body mass and height, clothing, amount of physical activity, individual heat tolerance, sunlight and ultraviolet radiation exposure, and the wind speed. Significant deviations from these will result in heat index values which do not accurately reflect the perceived temperature.

In Canada, the similar humidex (a Canadian innovation introduced in 1965) is used in place of the heat index. While both the humidex and the heat index are calculated using dew point, the humidex uses a dew point of 7 °C (45 °F) as a base, whereas the heat index uses a dew point base of 14 °C (57 °F). Further, the heat index uses heat balance equations which account for many variables other than vapor pressure, which is used exclusively in the humidex calculation. A joint committee formed by the United States and Canada to resolve differences has since been disbanded.

In the summer of 1979, while employed by National Oceanic and Atmospheric Association (NOAA) and between semesters at Saint Louis University, Daniel J Mosley co-developed the FORTRAN program that calculated the heat humidity index, first termed the "Humidex." He incorporated seven indices in the program based on Steadman's work. He did this while progressing towards his PhD in Biology.