Under normal conditions, the heart's sinoatrial node (SA node) determines the rate by which the organ beats – in other words, it is the heart's "pacemaker". The electrical activity of sinus rhythm originates in the sinoatrial node and depolarizes the atria. Current then passes from the atria through the atrioventricular node and into the bundle of His, from which it travels along Purkinje fibers to reach and depolarize the ventricles. This sinus rhythm is important because it ensures that the heart's atria reliably contract before the ventricles, ensuring as optimal stroke volume and cardiac output.

In junctional rhythm, however, the sinoatrial node does not control the heart's rhythm – this can happen in the case of a block in conduction somewhere along the pathway described above, or in sick sinus syndrome, or many other situations. When this happens, the heart's atrioventricular node or bundle of His can take over as the pacemaker, starting the electrical signal that causes the heart to beat. Depending on where the rhythm originates in the AV node, the atria can contract before ventricular contraction due to retrograde conduction, during ventricular contraction, or after ventricular contraction. If there is a blockage between the AV node and the SA node, the atria may not contract at all.

Junctional rhythm can be diagnosed by looking at an ECG: it usually presents without a P wave or with an inverted P wave. Retrograde, or inverted, P waves refers to the depolarization from the AV node back towards the SA node.

Classification

Junctional bradycardia

Junctional bradycardia is a rhythm that still originates in the AV node or bundle of His, but simply beats at a rate less than 40 beats per minute.

Junctional escape rhythm

Junctional escape rhythm is a rhythm that still originates in the AV node or bundle of His, but beats at the intrinsic automaticity of the AV node, between 40 and 60 beats per minute.

Accelerated junctional rhythm

Accelerated junctional rhythm is when the rhythm of emerged impulses is more than 40 to 60 beats per minute, which is the natural range of the junction. It happens in some instances such as digoxin toxicity, and usually has a rate of between 60 and 100 bpm.

Junctional tachycardia

Junctional tachycardia is a rhythm that still originates in the AV node or bundle of His, but simply beats at a rate above 100 beats per minute.