Peaking power plant

Reserved for high demand times

  • 6 min read
  • 4 chapters

Related on Lably

Through Power station, Electricity and Coal

Although historically peaking power plants were frequently used in conjunction with coal baseload plants, peaking plants are now used less commonly. Combined cycle gas turbine plants have two or more cycles, the first of which is very similar to a peaking plant, with the second running on the waste heat of the first. That type of plant is often capable of rapidly starting up, albeit at reduced efficiency, and then over some hours transitioning to a more efficient baseload generation mode. Combined cycle plants have similar capital cost per watt to peaking plants, but run for much longer periods, and use less fuel overall, and hence give cheaper electricity.

As of 2020, open cycle gas turbines give an electricity cost of around $151–198/MWh.

Peaker plants have been replaced with battery storage in some places. The New York Power Authority (NYPA) is seeking to replace gas peaker plants with battery storage, 142 Tesla Megapacks (providing 100 MW) replaced a gas peaker plant in Ventura County, California and in Lessines, Belgium 40 Tesla Megapacks (50 MW) replaced a turbojet generator. Australia's Clean Energy Council found in April 2021 that battery storage can be 30% cheaper than gas peaker plants.

Peak hours

Peak hours usually occur in the morning or late afternoon/evening depending on location. In temperate climates, peak hours often occur when household appliances are heavily used in the evening after work hours. In hot climates, the peak is usually late afternoon when air conditioning load is high, during this time many workplaces are still open and consuming power. In cold climates, the peak is in the morning when space heating and industry are both starting up.

A peaker plant may operate many hours a day, or it may operate only a few hours per year, depending on the condition of the region's electrical grid. Because of the cost of building an efficient power plant, if a peaker plant is only going to be run for a short or highly variable time, it does not make economic sense to make it as efficient as a base load power plant. In addition, the equipment and fuels used in base load plants are often unsuitable for use in peaker plants because the fluctuating conditions would severely strain the equipment. For these reasons, nuclear, waste-to-energy, coal and biomass are rarely, if ever, operated as peaker plants.