When underground sewer lines are laid close to the ground level (this may be at the depths of less than 0.75 metres (2.5 ft) or 2 metres (6.6 ft) depending on local regulations), an inspection chamber is used as an access point instead. Inspection chambers allow access to sewer lines without requiring a person to get in them.

Locations

Sanitary manholes should be constructed at locations where there is a change from a simple straight sewer line. These include all junctions that combine multiple lines into one or split from one, bends, changing in elevation, changing in pipe size, and changing in pipe type.

For straight sewer lines, there is no universal agreement on spacing requirements of sanitary manholes for such lines. Historically, in business cores of urban areas in the United States, manholes may be placed at each and every street block, 300 to 400 feet (91 to 122 m) apart. A more modern guideline in the United States suggested to have them every 400 feet (120 m) for small diameter sewers, and every 500 feet (150 m) for larger sewer mains. Similar spacing guidelines of 120 m and 150 m can be seen in Canada with specificities on sewer diameters. England sets maximum spacing at 90 metres (300 ft). The only exception is for sewers with diameters larger than human heights. Those can have spacing up to 200 metres (660 ft). Maximum spacing of 100 metres (330 ft) is used in Scotland. The 120-metre (390 ft) requirement is used in Brazil, and 150-metre (490 ft) in South Africa.