Lably
Skip to content

Zero heating building

Building without heating demand

  • 5 min read
  • 4 chapters

Related on Lably

Through Renewable energy, Product differentiation and Indoor air quality

Concept and approach

Seasonal energy storage problem

In areas where there is substantial heating demand, it is hard to fill this demand with renewable power as in heating season, solar power is in short supply. This means heating in highly urbanized areas is directly or indirectly powered by, in a large part from fossil sources. About 2000 TWh of seasonal energy storage is needed to meet EU's winter heating demand, should it be alleviated from fossil fuel dependency. Since heating is partially routed through electricity (e.g., heat-pumps) there is also a clear need for seasonal electricity storage. In Germany alone, about 40 TWh seasonal storage is required. The zero-heating building overcomes the need for major societal infrastructural changes required by the net-zero energy buildings and thus addresses major concerns.

Zero heating building as a continuation of the Passive house

Zero-heating buildings are built in the similar way as Passive houses while taking advantage in the recent developments in ultra-low U-value glazing. It has been shown that for buildings with window U-values approaching 0.3 W/(m2K) the heating demand diminishes. In this way, the building would not need a winter power reserve, and it obviously would not need any seasonal energy storage. Buildings built according to Passive-house standard can provide for removal of the central heating appliance with an only small auxiliary heating provision in the ventilation system.

First examples

In 1995, Wolfgang Feist demonstrated that with a glazing U-value of 0.3 W/(m2K) zero-heating buildings could be realized. The first purpose build (nearly) zero heating building is an office building, built in Rakvere, Estonia in 2014. Since 2015, more examples have been built based on the novel ultra-low U-value glazing.

Further developments of the Zero-heating building

A zero-heating building is proposed as a cornerstone of a market acceptable solution to the problem of the CO2 mitigation through reduction of the need for seasonal energy storage. Above the reduction of the need for energy storage, there are deletions in shading and truncation in heating arrangements. Abandoning now common modulated external shades and switching to more cost-efficient multipane glazing with built-in solar control glass somewhat increases cooling demand. The zero-heating building should be designed to keep cooling demand, Q'NC, less than 20 kWh/(m2a) for office buildings and less than 15 kWh/(m2a) for all other types. After capitalizing on the effects made by nearly zero-heating building one can further equip such a building with PV, to obtain something of a winter positive energy building which could in principle speed-up alleviation of societal energy problems by providing extra power on time. The remaining cooling and ventilation demand can thus be favorably synchronized with solar radiation, where maximum photovoltaic generation nearly coincides with the maximum power needed for cooling.

Sign in to keep reading

3 more chapters are free with a Lably account.

More in Energy