Lably
Skip to content

RAID

Data storage technology

  • 23 min read
  • 8 chapters

Related on Lably

Through Computer, Complexity and Availability

RAID levels are distinguished by the amount of redundancy they afford and the minimum number of drives they require, as well as by their relative complexity, performance, energy efficiency, fault tolerance, and availability. The definitive techniques used by RAID were conceived in the 1970s and 1980s: data striping to improve read/write efficiency, and disk mirroring or parity drives for data recovery. With the exception of RAID 1, all of the standard RAID levels use storage virtualization to abstract multiple storage devices into one logical storage volume.

In its original coinage, RAID is an acronym for redundant array of inexpensive disks. The RAID Advisory Board (est. 1992) later redefined the acronym to mean redundant array of independent disks. Before the advent of data striping and redundant, online disks, it was common for high-capacity, high-availability data storage to rely on so-called SLEDs ("single, large, expensive disks") connected to mainframe computers. RAID has been deployed not only in mainframe computers, but in personal computers, supercomputers, file servers, database servers, web servers, and network-attached storage appliances.

History

The term RAID was coined by David Patterson, Garth Gibson, and Randy Katz at the University of California, Berkeley in 1987. In their June 1988 paper "A Case for Redundant Arrays of Inexpensive Disks (RAID)", presented at the SIGMOD Conference, they argued that the disk drives of the top-performing mainframe computers of the time could be outperformed by an array of the (comparatively inexpensive) disk drives that were manufactured for the growing personal computer market. Although incidence of hard disk drive failure rises in proportion to the number of drives in use, the reliability of an array could far exceed that of any single, high-capacity drive if one built redundancy into the computer storage system by configuring it to write data to more than one disk automatically.

Although not yet using that terminology, the technologies of the five levels of RAID named in the June 1988 paper were used in various products prior to the paper's publication, including the following:

  • Mirroring (RAID 1) was well established in the 1970s including, for example, Tandem NonStop Systems.
  • In 1977, Norman Ken Ouchi at IBM filed a patent disclosing what was subsequently named RAID 4.
  • Around 1983, DEC began shipping subsystem mirrored RA8X disk drives (now known as RAID 1) as part of its HSC50 subsystem.
  • In 1986, Clark et al. at IBM filed a patent disclosing what was subsequently named RAID 5.
  • Around 1988, the Thinking Machines' DataVault used error correction codes (now known as RAID 2) in an array of disk drives. A similar approach was used in the early 1960s on the IBM 353.

Industry manufacturers later redefined the RAID acronym to stand for "redundant array of independent disks".