Lably
Skip to content

Digital holographic microscopy

Quantitative phase microscope

  • 12 min read
  • 4 chapters

Related on Lably

Through Microscopy, Wavefront and Lens

Holography was invented by Dennis Gabor to improve electron microscopy. Nevertheless, it never found many concrete and industrial applications in this field.

Actually, DHM has mostly been applied to light microscopy. In this field, it has shown unique applications for 3D characterization of technical samples and enables quantitative characterization of living cells. In materials science, DHM is routinely used for research in academic and industrial labs. Depending on the application, microscopes can be configured for both transmission and reflection purposes. DHM is a unique solution for 4D (3D + time) characterization of technical samples, when information needs to be acquired over a short time interval. It is the case for measurements in noisy environments, in presence of vibrations, when the samples move, or when the shape of samples change due to external stimuli, such as mechanical, electrical, or magnetic forces, chemical erosion or deposition and evaporation. In life sciences, DHM is usually configured in transmission mode. This enables label-free quantitative phase measurement (QPM), also called quantitative phase imaging (QPI), of living cells. Measurements do not affect the cells, enabling long-term studies. It provides information that can be interpreted into many underlying biological processes as explained in the section "Living cells imaging" below.

Working principle

To create the necessary interference pattern, i.e., the hologram, the illumination needs to be a coherent (monochromatic) light source, a laser for example. As can be seen in Figure 2, the laser light is split into an object beam and a reference beam. The expanded object beam illuminates the sample to create the object wave front. After the object wave front is collected by a microscope objective, the object and reference wave fronts are joined by a beam splitter to interfere and create the hologram. Using the digitally recorded hologram, a computer acts as a digital lens and calculates a viewable image of the object wave front by using a numerical reconstruction algorithm.

Commonly, a microscope objective is used to collect the object wave front. However, as the microscope objective is only used to collect light and not to form an image, it may be replaced by a simple lens. If a slightly lower optical resolution is acceptable, the microscope objective may be entirely removed.

Digital holography comes in different flavors, such as off-axis Fresnel, Fourier, image plane, in-line, Gabor and phase-shifting digital holography, depending on the optical setup. The basic principle, however, is the same; a hologram is recorded and an image is reconstructed by a computer.

The lateral optical resolution of digital holographic microscopy is equivalent to the resolution of traditional light microscopy. DHM is diffraction-limited by the numerical aperture, in the same way as traditional light microscopy. However, DHM offers a superb axial (depth) resolution. An axial accuracy of approximately 5 nm has been reported.

Sign in to keep reading

3 more chapters are free with a Lably account.

More in Physics